System type

Housing

Circuits

Battery compartment

Supply power 1 h

Supply power 3 h

Supply power 8 h
Navigation und Filter

LPS - microControl plus series

Low power system

MICROCONTROL PLUS – THE POWER SUPPLY SYSTEM FOR THE SUPPLY OF FIRE COMPARTMENTS

The microControl plus is a decentralized power supply system with limited power (LowPower system) for a 1 -, 3 - or 8-hour operation. This system combines the high reliability of a decentralized single-battery system with the ease and comfort of a central battery system.

Through the principle of decentralization per fi re compartment, similar to a single battery system,  there will be no costs for E30-powerlines and their installation according to german regulations. The microControl is installed in an electrical service room in each fi re compartment. microControl plus works in switched mode 230VAC or 216VDC and can be equipped with up to 6 main circuits. One additional circuit is installed by default. This assures the possibility to connect conventional luminaires with electronic ballast and an input voltage of 230V AC/DC. In combination with our innovative LED luminaires energy effi  ciency, durability, and lighting improvements in all parts of the building can be optimized.

The integrated browser-based visualization software makes the system capable to monitor all connected emergency and rescue route luminaires and report immediately in case of failure.

A certified E30-cabinet is available optional. DIBt-Certifi cation No. Z-86.2-56.

• Low power system acc. to DIN EN 50171 for security lighting systems acc. to DIN EN 50172 and systems acc. to DIN VDE 0100- 718

• automated monitoring system acc. to DIN EN 62034 for regular testing of all connected luminaires

• independant system with combined switching for non-maintained, maintained and switched maintained luminaires

• test records are stored für 5 years

• different interface languages possible

• Management and failure monitoring for up to 20 luminaires
per circuit

• 4 main circuits and one circuit in non-maintained or maintained
mode with max. 150 VA (programmable)

• maximum connected load (mains) of 800 VA

• Information reports about the system, circuits and luminaires as
plain text and Control-LED

• Connectivity for additional external switch interrogation
modules via RS485 interface

• Up to 6 control inputs can be assigned to each circuit

• Networking of multible devices via Ethernet (TCP/IP) as option

• integrated Web - Server for remote maintenance of the system, visualization of floor plans and much more

Internal light switch query module SAM:

· 4 light switch inputs (200-255 VAC or 24-255 VDC)

· Power supply for internal connection with terminal connector

· 6 switching modes programmable

Internal IO module:

· 3 relay outputs, 230V / 6 A, isolated change-over contacts

· 1 galvanically isolated input 24 V DC – 230 V AC, selectable polarity, user defined message text and function

· Up to 5 modules (multi-bus)

Internal CCIF - Critical Circuit Interface module

· Surveillance of closed current loop

· Internal protection against overvoltage

MICROCONTROL PLUS – THE POWER SUPPLY SYSTEM FOR THE SUPPLY OF FIRE COMPARTMENTS

The microControl plus is a decentralized power supply system with limited power (LowPower system) for a 1 -, 3 - or 8-hour operation. This system combines the high reliability of a decentralized single-battery system with the ease and comfort of a central battery system.

Through the principle of decentralization per fi re compartment, similar to a single battery system,  there will be no costs for E30-powerlines and their installation according to german regulations. The microControl is installed in an electrical service room in each fi re compartment. microControl plus works in switched mode 230VAC or 216VDC and can be equipped with up to 6 main circuits. One additional circuit is installed by default. This assures the possibility to connect conventional luminaires with electronic ballast and an input voltage of 230V AC/DC. In combination with our innovative LED luminaires energy effi  ciency, durability, and lighting improvements in all parts of the building can be optimized.

The integrated browser-based visualization software makes the system capable to monitor all connected emergency and rescue route luminaires and report immediately in case of failure.

A certified E30-cabinet is available optional. DIBt-Certifi cation No. Z-86.2-56.

• Low power system acc. to DIN EN 50171 for security lighting systems acc. to DIN EN 50172 and systems acc. to DIN VDE 0100- 718

• automated monitoring system acc. to DIN EN 62034 for regular testing of all connected luminaires

• independant system with combined switching for non-maintained, maintained and switched maintained luminaires

• test records are stored für 5 years

• different interface languages possible

• Management and failure monitoring for up to 20 luminaires
per circuit

• 4 main circuits and one circuit in non-maintained or maintained
mode with max. 150 VA (programmable)

• maximum connected load (mains) of 800 VA

• Information reports about the system, circuits and luminaires as
plain text and Control-LED

• Connectivity for additional external switch interrogation
modules via RS485 interface

• Up to 6 control inputs can be assigned to each circuit

• Networking of multible devices via Ethernet (TCP/IP) as option

• integrated Web - Server for remote maintenance of the system, visualization of floor plans and much more

Internal light switch query module SAM:

· 4 light switch inputs (200-255 VAC or 24-255 VDC)

· Power supply for internal connection with terminal connector

· 6 switching modes programmable

Internal IO module:

· 3 relay outputs, 230V / 6 A, isolated change-over contacts

· 1 galvanically isolated input 24 V DC – 230 V AC, selectable polarity, user defined message text and function

· Up to 5 modules (multi-bus)

Internal CCIF - Critical Circuit Interface module

· Surveillance of closed current loop

· Internal protection against overvoltage



Circuits
Lights to be connected
Supply power 1h
Supply power 3h
Supply power 8h