lub
The 3-phase inverter is a powerful grid-connected device, which supplies solar power for self-consumption or for feeding into the grid.
Dane o produkcie
Maksymalna wydajność konwersji
98,7 %
Nominal Power
100 kW
Europejska efektywność
98,3 %
Max. AC-Wirkleistung (cosφ=1)
110 kW
Wydajność MPPT
>99 %
Nominal Voltage AC
220/380 230/400 V
Max. Power DC
150 kW
Rated AC Grid Frequency
50 / 60
Input Voltage DC
1000 V
Operating Phase
3P
Input Voltage DC
250 V
Output Current
144,9 A
MPPT-Operating Range
200~850 V
Max. Output Current
159,4 A
Max. Input Power
40+40+40+40+40+40 A
Output Power factor
>0,99
Max. Short Circuit Current
60+60+60+60+60+60 A
Output DC-Feed Current
<0,5 %
MPPT Strings
6 MPPT a 4 szt.
Frequency Range
47~52 oder 57~62
Reverse Polarity Protection DC
Tak
Short Circuit Protection AC
Tak
Overcurrent Protection AC-Output
Tak
Output Overvoltage Protection
Tak
Insulation Resistance Protection
Tak
Earth Fault Monitoring
Tak
Island Effect Protection
Tak
Temperature Protection
Tak
Integrated DC-Switch
Tak
Remote Software Upload
Tak
Parameter Change
Tak
Overvoltage Protection
DC Typ II / AC Typ II
Length
838 mm
Width
568 mm
Height
323 mm
Weight
73,7 kg
Topology
Transformatorlos
Self Consumption
<1W (Nacht)
Min. Temp
-25 °C
Max. Temp
65 °C
Stopień ochrony (IP)
IP65
Noise
<55dB
Cooling Concept
Integrierte Lüfter
Max. Operating Altitude
2000 m
Warranty
5
Mains Connection Standard
EN50549-1, VDE 0124-1-1, VDE-AR-N 4105:2018-11, VDE-V 0124- 100:2022-06
Humidity
0-100%
Safety-EMV
IEC62109-1/-2, IEC61000-6-2, IEC61000-6-4
DC-Connector
MC4 Steckbar
AC- Connector
Schraubklemmen
Display
LCD 240 x 160
Interface
RS485/RS232/Wifi/LAN
Maksymalna wydajność konwersji
98,7 %
Europejska efektywność
98,3 %
Wydajność MPPT
>99 %
Max. Power DC
150 kW
Input Voltage DC
1000 V
Input Voltage DC
250 V
MPPT-Operating Range
200~850 V
Max. Input Power
40+40+40+40+40+40 A
Max. Short Circuit Current
60+60+60+60+60+60 A
MPPT Strings
6 MPPT a 4 szt.
Nominal Power
100 kW
Max. AC-Wirkleistung (cosφ=1)
110 kW
Nominal Voltage AC
220/380 230/400 V
Rated AC Grid Frequency
50 / 60
Operating Phase
3P
Output Current
144,9 A
Max. Output Current
159,4 A
Output Power factor
>0,99
Output DC-Feed Current
<0,5 %
Frequency Range
47~52 oder 57~62
Reverse Polarity Protection DC
Tak
Short Circuit Protection AC
Tak
Overcurrent Protection AC-Output
Tak
Output Overvoltage Protection
Tak
Insulation Resistance Protection
Tak
Earth Fault Monitoring
Tak
Island Effect Protection
Tak
Temperature Protection
Tak
Integrated DC-Switch
Tak
Remote Software Upload
Tak
Parameter Change
Tak
Overvoltage Protection
DC Typ II / AC Typ II
Length
838 mm
Width
568 mm
Height
323 mm
Weight
73,7 kg
Topology
Transformatorlos
Self Consumption
<1W (Nacht)
Min. Temp
-25 °C
Max. Temp
65 °C
Stopień ochrony (IP)
IP65
Noise
<55dB
Cooling Concept
Integrierte Lüfter
Max. Operating Altitude
2000 m
Warranty
5
Mains Connection Standard
EN50549-1, VDE 0124-1-1, VDE-AR-N 4105:2018-11, VDE-V 0124- 100:2022-06
Humidity
0-100%
Safety-EMV
IEC62109-1/-2, IEC61000-6-2, IEC61000-6-4
DC-Connector
MC4 Steckbar
AC- Connector
Schraubklemmen
Display
LCD 240 x 160
Interface
RS485/RS232/Wifi/LAN