Visit us! From 1 to 3 October 2024 in Riyadh (Saudi Arabia) – Hall 4 / Stand C40
LPS - miniControl plus series
MINICONTROL (XL) PLUS – DECENTRALIZED POWER SUPPLY WITH UP TO 1.500 W
The Low Power System miniControl plus closes the gap between the smaller powered my-/microControl plus and the big brothers midi-/ multiControl plus.
miniControl (XL) plus is a decentralized power supply system with limited power (LowPower system) for a 1 -, 3 - or 8-hour operation. This system combines the high reliability of a decentralized single-battery system with the ease and comfort of a central battery system.
Through the principle of decentralization per fi re compartment similar to a single battery system acc. to MLAR 2005 there will be no costs for E30-powerlines and their installation. The miniControl (XL) plus works in switched mode 230VAC or 220VDC and can be equipped with up to 12 main circuits (32 main circuits for miniControl XL). One additional circuit is installed by default for miniControl plus. This assures the possibility to connect conventional luminaires with electronic ballast and an input voltage of 230V AC/ DC. In combination with our innovative LED luminaires energy effi ciency, durability and lighting improvements in all parts of the building can be optimized.
The integrated browser-based visualization software makes the system capable to monitor all connected emergency and rescure route luminaires and report immediately in case of failure.
A certifi ed E30-cabinet (not suitable for miniControl XL) is available optionally. DIBt-Certifi cation No. Z-86.2-55.
Case material: steel-sheet RAL 7035 1100x500x230mm (miniControl) (Fire resistant cabinet optional) 1470x571x230mm (miniControl XL)
Protection category: IP20
Insulation class: I
Voltage: 230V AC (±10%) 50/60Hz
Switched mode: 230V AC / 216V DC ±15%
Battery (included): 216V DC (18 x 12V /17Ah)
Battery power 1h: 6,98A / ~1500W
(incl. 25% aging reserve): 3h: 2,3A / ~500W 8h: 1,4A / ~300W
Permissible temp.: 10° to 35° C
max. connected load AC: 2.000 VA
max. connected load DC: 1.500W* (1 hour) 500W* (3 hours) 300W* (8 hours)
• Low power system acc. to DIN EN 50171 for security lighting systems acc. to DIN EN 50172 and systems acc. to DIN VDE 0100- 718
• automated monitoring system acc. to DIN EN 62034 for regular testing of all connected luminaires
• independant system with combined switching for non-maintained, maintained and switched maintained luminaires
• test records are stored für 5 years
• different interface languages possible
• Management and failure monitoring for up to 20 luminaires
per circuit
• 4 main circuits and one circuit in non-maintained or maintained
mode with max. 150 VA (programmable)
• maximum connected load (mains) of 800 VA
• Information reports about the system, circuits and luminaires as
plain text and Control-LED
• Connectivity for additional external switch interrogation
modules via RS485 interface
• Up to 6 control inputs can be assigned to each circuit
• Networking of multible devices via Ethernet (TCP/IP) as option
• integrated Web - Server for remote maintenance of the system, visualization of floor plans and much more
Internal light switch query module SAM:
· 4 light switch inputs (200-255 VAC or 24-255 VDC)
· Power supply for internal connection with terminal connector
· 6 switching modes programmable
Internal IO module:
· 3 relay outputs, 230V / 6 A, isolated change-over contacts
· 1 galvanically isolated input 24 V DC – 230 V AC, selectable polarity, user defined message text and function
Internal CCIF - Critical Circuit Interface module
· Surveillance of closed current loop
· Internal protection against overvoltage
MINICONTROL (XL) PLUS – DECENTRALIZED POWER SUPPLY WITH UP TO 1.500 W
The Low Power System miniControl plus closes the gap between the smaller powered my-/microControl plus and the big brothers midi-/ multiControl plus.
miniControl (XL) plus is a decentralized power supply system with limited power (LowPower system) for a 1 -, 3 - or 8-hour operation. This system combines the high reliability of a decentralized single-battery system with the ease and comfort of a central battery system.
Through the principle of decentralization per fi re compartment similar to a single battery system acc. to MLAR 2005 there will be no costs for E30-powerlines and their installation. The miniControl (XL) plus works in switched mode 230VAC or 220VDC and can be equipped with up to 12 main circuits (32 main circuits for miniControl XL). One additional circuit is installed by default for miniControl plus. This assures the possibility to connect conventional luminaires with electronic ballast and an input voltage of 230V AC/ DC. In combination with our innovative LED luminaires energy effi ciency, durability and lighting improvements in all parts of the building can be optimized.
The integrated browser-based visualization software makes the system capable to monitor all connected emergency and rescure route luminaires and report immediately in case of failure.
A certifi ed E30-cabinet (not suitable for miniControl XL) is available optionally. DIBt-Certifi cation No. Z-86.2-55.
Case material: steel-sheet RAL 7035 1100x500x230mm (miniControl) (Fire resistant cabinet optional) 1470x571x230mm (miniControl XL)
Protection category: IP20
Insulation class: I
Voltage: 230V AC (±10%) 50/60Hz
Switched mode: 230V AC / 216V DC ±15%
Battery (included): 216V DC (18 x 12V /17Ah)
Battery power 1h: 6,98A / ~1500W
(incl. 25% aging reserve): 3h: 2,3A / ~500W 8h: 1,4A / ~300W
Permissible temp.: 10° to 35° C
max. connected load AC: 2.000 VA
max. connected load DC: 1.500W* (1 hour) 500W* (3 hours) 300W* (8 hours)
• Low power system acc. to DIN EN 50171 for security lighting systems acc. to DIN EN 50172 and systems acc. to DIN VDE 0100- 718
• automated monitoring system acc. to DIN EN 62034 for regular testing of all connected luminaires
• independant system with combined switching for non-maintained, maintained and switched maintained luminaires
• test records are stored für 5 years
• different interface languages possible
• Management and failure monitoring for up to 20 luminaires
per circuit
• 4 main circuits and one circuit in non-maintained or maintained
mode with max. 150 VA (programmable)
• maximum connected load (mains) of 800 VA
• Information reports about the system, circuits and luminaires as
plain text and Control-LED
• Connectivity for additional external switch interrogation
modules via RS485 interface
• Up to 6 control inputs can be assigned to each circuit
• Networking of multible devices via Ethernet (TCP/IP) as option
• integrated Web - Server for remote maintenance of the system, visualization of floor plans and much more
Internal light switch query module SAM:
· 4 light switch inputs (200-255 VAC or 24-255 VDC)
· Power supply for internal connection with terminal connector
· 6 switching modes programmable
Internal IO module:
· 3 relay outputs, 230V / 6 A, isolated change-over contacts
· 1 galvanically isolated input 24 V DC – 230 V AC, selectable polarity, user defined message text and function
Internal CCIF - Critical Circuit Interface module
· Surveillance of closed current loop
· Internal protection against overvoltage